VFD motor speed calculator
With a VFD, the speed of an induction motor follows the frequency. Enter the nameplate speed (for example 1450 rpm at 50 Hz): the tool works out the number of poles and the slip, then gives the actual speed at the chosen frequency and the frequency to set to reach a target speed.
- Estimated motor speed
- 1000 rpm
- Frequency to set for the target speed
- 35 Hz
- Synchronous speed at this frequency
- 1050 rpm
- Number of poles
- 4
- Rated slip
- 50 rpm · 3.3 %
Indicative result: always verify against the standards and the installation method on site.
Publicité
Formula
ns=120×f/p
n≈ns−slip
Good to know
- Slip (in rpm) is taken as constant at rated load; at no load, the speed gets close to synchronous speed.
- Above 50 Hz the motor is in field weakening: speed rises but available torque drops.